A server cupboard, comms room or small equipment room is not a small data hall. It has less floor space, often no raised floor, and sometimes sits in the middle of an office. The way you cool it usually comes down to three things: how the room is laid out, how much heat is in it, and whether it can have its own dedicated plant.
This article compares the three ways NPS cools small rooms, using the NPS range, and sets out the questions that choose between them. It also covers what changes when a room outgrows the small room range. For the wider picture, including the cooling types used in larger facilities, read the NPS precision cooling guide, or Is Your Computer Room Cooling Protecting Your Power? for how cooling and UPS systems work together.
Why Small Rooms Need Precision Cooling
IT and communications equipment needs a narrow temperature and humidity band to run reliably. Comfort air conditioning is designed for people. Precision cooling runs continuously, controls humidity as well as temperature, and is sized to the heat load of the equipment in the room. Get it wrong and you risk thermal shutdowns, shortened hardware life and unplanned downtime.
STULZ describes its MiniSpace range as keeping computer systems cool much more precisely, economically, reliably and durably than conventional comfort air-conditioning systems.
If the room also holds a UPS, the stakes rise. Every UPS generates heat, and if the temperature is not managed that heat builds up and puts the equipment at risk. UPS battery capacity is rated at an ambient temperature of 20°C or 25°C, so operating outside that range can reduce performance and lifespan.
Three Ways to Cool a Small Room
| Option | How it works | Suits | NPS examples |
|---|---|---|---|
| Compact room unit | A floor-standing precision unit that cools the whole room, with downflow or upflow airflow and front access for service | Server cupboards, small and medium computer rooms, comms rooms, UPS and battery rooms, equipment rooms where a full-size CRAC unit will not fit | STULZ MiniSpace (heat loads up to 28kW), Vertiv Liebert DM (7.5kW and 12.5kW air-cooled) |
| Row-based cooling | A standalone unit placed in the row of racks, cooling at the heat source, with adjustable airflow or targeted rack cooling | Rooms with fluctuating or high-density rack loads, space restrictions, or no raised floor | STULZ CyberRow, Vertiv Liebert CRV |
| Integrated cabinet | A factory-built rack that contains its own power, cooling, power distribution, monitoring and security | Sites with no dedicated IT room, including offices | Vertiv SmartCabinet |
Browse the full small room cooling range, or see large room cooling for data halls and larger computer rooms.
The Three Options in the NPS Range
Liebert CRV
SmartCabinet™
Compact Room Units
This is the usual starting point for a room that needs whole-room cooling in a small footprint. The STULZ MiniSpace cools small server and equipment rooms with a heat load of up to 28 kilowatts. It works with a cooling compressor using air or liquid cooling (DX), or with chilled water, in downflow and upflow versions. The units need very little floor space, so they can be installed in existing server rooms, and their front doors make installation and maintenance simple. The Vertiv Liebert DM comes in 7.5kW and 12.5kW air-cooled versions with 100% front door access and an ECO-Mode option, and suits UPS and battery rooms, outdoor equipment rooms, transformer stations and storage rooms as well as small computer rooms.
Row-Based Cooling
Where the heat is concentrated in a few racks, or there is no raised floor, cooling placed in the row can do more than cooling that works on the whole room. The STULZ CyberRow is a standalone unit that is installed and operated independently of the rack and is independent of rack manufacturer. It is available in six sizes and four cooling systems, and cools high-density racks in a targeted way, with or without a raised floor. The Vertiv Liebert CRV is caster-mounted with adjustable baffles that send cool air to the servers, suits raised or non-raised floors, and needs only front and back access.
Integrated Cabinets
If there is no room to dedicate, the Vertiv SmartCabinet removes the need to build one. It is a fully integrated, factory-assembled and tested unit that contains power, thermal management, the rack enclosure, power distribution, monitoring and security, with a built-in UPS and cooling equipment. It runs fully closed, circulating cold and hot air within the rack, with dust protection and noise insulation that make it highly suitable for an office environment, and it is ready to use from day one.
Five Questions That Choose Between Them
- What is the heat load? Cooling is sized to the heat load of the equipment, not to the floor area. Over-sizing can raise energy costs, because the unit cycles on and off more and does not remove humidity well, while under-sizing leaves a unit running constantly and never reaching temperature.
- Is it a dedicated room, or a shared space? A shared or office space points towards a closed, quiet option such as the SmartCabinet.
- Is there a raised floor, and how much floor space is there? A compact room unit needs little floor space, and row-based cooling works without a raised floor.
- Is the load spread evenly or concentrated? High-density racks suit targeted row-based cooling.
- Is chilled water available? The MiniSpace and CyberRow offer chilled water systems as well as direct expansion, and the CRV is available in air, water, glycol and chilled water systems.
When the Room Outgrows the Cupboard
Rooms grow. A cupboard becomes a comms room, and a comms room becomes a small data hall. At that point the load moves into NPS’s large room cooling range, which is sized for whole-room heat loads in raised-floor and ducted facilities. NPS matches the cooling type and capacity to your load, your room and your redundancy requirements, so it is worth planning for growth when you choose the first unit.
- Vertiv Liebert PEX: a wide range of standard units from 20kW to 100kW in upflow and downflow configurations. It uses EC fans and a digital scroll compressor that manages capacity from 20 to 100 percent, and its iCOM teamwork mode lets multiple units work together as a single system. See the Liebert PEX.
- STULZ CyberAir 3: a stand-alone precision system for data centres and equipment rooms with a heat load of over 20kW, with indirect and direct free cooling. STULZ states it conditions the air up to 90% more economically than conventional compressor cooling systems. See the CyberAir 3.
- Vertiv SmartAisle: aisle containment. Without containment, hot and cold air mix in both aisles, which makes the cooling system less effective and less energy efficient. SmartAisle provides a uniform temperature and a consistently hot return air. The Liebert CRV can be used with it. See SmartAisle.
Cooling the UPS and Battery Room
Cooling and UPS systems are the two continuous loads in any critical room, so NPS sizes and maintains them together. A UPS room that runs hot shortens battery life, and a room with poor air quality adds a second risk: dust and poor environments are leading causes of UPS failure. The Liebert DM is suited to UPS and battery rooms, and has alarms for fan failure and filter clogging, with email and SMS notification through the Liebert RDU for remote monitoring. Every NPS UPS preventative maintenance visit includes battery health testing and an environmental assessment. Read more about UPS systems and battery maintenance and replacement.
Common Mistakes
- Treating the room like an office. Comfort air conditioning is not designed to run continuously or to control humidity.
- Sizing to floor area rather than heat load.
- Over-sizing to be safe, which wastes energy and removes humidity poorly.
- Planning cooling separately from the UPS, racks and monitoring.
- Skipping maintenance. NPS recommends a regular monthly health check that covers refrigerant levels, filters and airflow, and checks that the CRAC and condenser systems are working within the safe zone.
- Having no alarms, so a cooling failure is discovered after the equipment has overheated.
How NPS Can Help
NPS is an authorised STULZ and Vertiv Liebert partner, and designs, supplies, installs and maintains precision cooling from a single server cupboard to a full data hall. Turnkey power solutions cover heat-load assessment, cooling design and integration with your UPS, racks and power distribution as a single project. NPS commissions cooling against the room’s design heat load, and maintains STULZ and Vertiv Liebert units, including filters, refrigerant and controls. For over 30 years NPS has supplied and maintained critical infrastructure across Australia and New Zealand, with offices in Sydney, Melbourne, Brisbane and Perth. For small remote sites, see edge computing power and infrastructure and racks and cabinets.
Frequently Asked Questions About Small Server Room Cooling
Can I use a standard air conditioner to cool a server room?
Comfort air conditioning is designed for people. Precision cooling runs continuously, controls humidity as well as temperature, and is sized to the heat load of the equipment in the room. NPS can assess your room and recommend the right cooling for it.
How much cooling does a small server room need?
Cooling is sized to the heat load of the equipment in the room, not to the floor area. Over-sizing wastes energy and removes humidity poorly, and under-sizing leaves the unit running constantly without reaching temperature. NPS carries out a heat-load assessment as part of its turnkey service.
What is in-row cooling?
In-row cooling uses units placed between the racks, close-coupled to high-density loads for efficient, targeted heat removal. The STULZ CyberRow and Vertiv Liebert CRV are row-based units in the NPS range.
Do I need a dedicated server room?
Not always. The Vertiv SmartCabinet contains power, cooling, power distribution, monitoring and security in a single factory-built cabinet, and no dedicated IT room is required.
Does a UPS need cooling?
Yes. Every UPS generates heat, and if the temperature is not managed that heat can build up and put your equipment at risk. UPS batteries are rated at an ambient temperature of 20°C or 25°C, and operating outside that range can reduce performance and lifespan.
How often should server room cooling be serviced?
NPS recommends a regular monthly health check that covers refrigerant levels, filters and airflow, and confirms that the CRAC and condenser systems are working within the safe zone.
When do I need large room cooling instead of small room cooling?
Large room cooling is for data halls, larger computer rooms, and raised-floor or ducted facilities, and is sized for whole-room heat loads. The NPS large room range includes the Vertiv Liebert PEX, with standard units from 20kW to 100kW, and the STULZ CyberAir 3 for heat loads of over 20kW. NPS can assess your load and tell you which range suits the room.
What small room cooling does NPS supply?
NPS supplies and services small room cooling from STULZ and Vertiv Liebert, including the STULZ MiniSpace and Vertiv Liebert DM ranges with capacities up to 28kW, the STULZ CyberRow, the Vertiv Liebert CRV and the Vertiv SmartCabinet.
Talk to NPS About Cooling Your Room
If you are deciding how to cool a server cupboard, comms room or equipment room, NPS can assess the heat load and recommend the right option. Explore the precision cooling range, or contact the team to talk through your room.